Digital Security Controls PC1575 Installationshandbuch Seite 56

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 110
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 55
43
Bypass Memory
Uploads the Bypass Memory status of each zone.
“Yes” indicates the zone was bypassed the last time that zones
were bypassed
“No” indicates the zone was not bypassed the last time that zones
were bypassed.
Panel Time and Date
Uploads the current time (HH:MM:SS) and date (MM/DD/YY) from the control
panel and displays the information on the main status screen.
Quick Exit (PC40X0 only) Special Message (PC40X0 only)
Quick Arm (PC40X0 only) Schedule Arm (PC40X0 v2.x)
Auto Arm Shedule Disarm (PC40X0 v2.x)
Door Chime
These sections upload the enabled status of the selected features for each
partition of the panel. The information is displayed on the main status screen.
“Yes” indicates the feature is enabled
“No” indicates the feature is disabled.
“Sch” indicates that Schedule Arm is enabled (PC40X0 v2.x only).
Keypad Lockout
Uploads the Keypad Lockout Status for each partition.
“Yes” indicates the partition is presently locked out as too many
incorrect Access Codes were entered on a keypad
“No“ indicates the partition is not presently locked out.
Fire Troubles (PC40X0 files only)
Uploads the Fire Trouble Status of each partition. To determine which zone is
causing the trouble, upload the zone status.
• “Yes” indicates a trouble with the fire detection circuits on that
partition
“No“ indicates there are no troubles with the fire detection circuits
on that partition.
Panel In Alarm
Uploads the Alarm Status of each partition.
“Yes” indicates the partition is in alarm
“No” indicates the partition is not in alarm.
Only audible burglar alarms are considered to be an alarm. The partition will not
show an alarm for fire alarms, silent alarms or after bell timeout.
Trouble Memory / Trouble Status
Uploads the status of the trouble conditions:
“Yes” indicates a trouble condition is present
“No” indicates a trouble condition is not present.
Panel Programmed (PC40X0 files only)
Uploads the panel’s programmed status.
“Yes” indicates someone has entered the [
*
][8] Installer‘s
Programming Command since the last time uploading/downloading
was performed
“No“ indicates the [
*
][8] Installer’s Command has not been used.
This feature is useful for monitoring unauthorized programming in the Installer
Section, and indicates that information in the Work File may not be current.
Seitenansicht 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 109 110

Kommentare zu diesen Handbüchern