17
PC2525: Preparation for Downloading:
A Note the Downloading Access Code in section [72] and the Panel Identifier Code in
section [73] so that you can enter the same values into the DLS-1 customer work
file.
B In Section [74], set the number of rings the panel will wait before it answers. In Section
[70]: enable Ring Detect at option [1]; if the panel is to initiate downloading calls,
enable User Initiated Call Up at option [2]; if there is an answering machine
connected to the same phone line as the panel, enable the Answering Machine
Connected feature at option [3]; enable the Call Back feature at option [4].
C If User Initiated Callup or the Callback feature is enabled, a Downloading Call
Back Telephone Number must be programmed in Section [71].
PC1575/1580: Preparation for Downloading — Using a Modem
A Make note of the Download Access Code in section [73] and the Panel Identifier Code
in section [74] so that you can enter the same values into the DLS-1 customer work file.
B The PC1575/1580 has a time-limited DLS answer window for added security. After
the panel is powered-up, it will answer calls for a 6-hour period. This feature allows
you to perform downloading without having to do keypad programming. The panel
will answer after 12 rings, or following the Answering Machine Override format (
see
section 3.3
).
Downloading can also be enabled by the user through User Functions when the
“User Can Enable DLS Window” option is enabled (section [71], option [2]). When
the user enters [
∗
][6][Master Code][5] at any keypad, the panel will answer the
phone for a 1-hour period.
The PC1575/1580 can also be programmed to always answer a call on the
programmed number of rings, by enabling option [1], section [71]. If there is an
answering machine on the same phone line as the panel, enable the “Answering
Machine Override” feature (section [71], option [6]). This will always answer the
phone on a double-call.
C You may enable the Callback Option if you require this security feature (section
[71], option [3]). If Callback is enabled, the Downloading phone number must be
programmed in section [72].
PC1575/1580: Preparation for Downloading — Using PC-Link
A Note the Downloading Access Code in section [73] so that you can enter the same
value into the DLS-1 customer work file.
PC1550: Preparation for Downloading:
A Follow step A for the PC1500.
B The PC1500 steps B & C are only necessary if you wish the PC1550 to Initiate a
Callup.
C Section [31] must have option [1] turned on to enable downloading. Option [3]
should be on to enable the Answering Machine feature. To use the Call Back
feature, enable option [2]. Set the number of rings for answer in section [29]. For the
Call Back feature, program the downloading phone number in section [26].