wiring has been cut or otherwise does not form a complete loop. This will
only occur if the system has been programmed for Double End-of-Line
Resistor Zone operation.
• “Trbl” indicates the zone is presently in a trouble condition. This means that
the zone wiring has been cut or otherwise does not form a complete loop.
The condition will only occur for Supervisory Zones (such as 24-Hour Fire,
Delayed Fire, Auto-Verify Fire and LINKS Supervisory zones).
PC4020 and PC4010 v2.x:
“O” indicates the zone is presently secure
“S” indicates the zone is presently faulted (shorted). This will only occur if
the zone is using Double End of Line Resistor Zone Operation.
“T” indicates the zone is presently in a tampered condition. This
means the zone wiring has been cut or otherwise does not form a
complete loop.
“V” indicates the zone is not secure.
• “R” indicates the zone is presently in a Trouble condition. This
means that the zone wiring has been cut or otherwise does not
form a complete loop. The condition will only occur for Supervisory
Zones (such as 24-hour fire, Delayed fire, Auto-Verify fire, and
Links Supervisory Zones).
“F” indicates that a wireless RF zone is not communicating with
the panel.
“L” indicates that a wireless RF zone's batteries are low and need
to be replaced.
“M” indicates that a wireless RF zone has been tampered with and
removed from it's backplate.
PC5015, PC5010, PC5008, PC1575/1580, PC1565-2P, PC1555/1565
and PC580/585:
“OK” indicates the zone is presently secure.
“Open” indicates the zone is not secure.
“Tmpr” indicates the zone is presently in a tampered condition.
This means the zone wiring has been cut or otherwise does not
form a complete loop.
“Fault” indicates the zone is presently faulted (shorted).
“LoBat” indicates that a wireless RF zone's batteries are low and
need to be replaced (PC5015, PC5010, PC5008, PC1565-2P,
PC1555/1565 and PC580/585).
“• •” indicates the zone does not exist or is not enrolled.
Arm/Disarm
Uploads the armed status of each partition.
“No” indicates the partition is disarmed
“Yes” indicates the partition is armed.
Alarm Memory
Uploads the Alarm Memory Status of each zone.
“Yes” indicates the zone was in alarm during last armed period
“No” indicates the zone was not in alarm
Bypass Zones
Uploads the bypass status of each zone. This does not include Home-Away
zones that were bypassed automatically; only manually bypassed zones are
displayed.