Escort4580
Voice Prompt
Security & Building
Automation Control Module
• Turns any touch tone phone
into a fully functional keypad with
both Global and Partition control
• Module contains extensive
library of voice prompts for security
and building automation control and
status feedback
• Up to 6 words per voice prompt,
chosen from a 241 word library
• Built-in Power Line interface for
up to 32 X-10 control devices
• Program event activation of X-10
devices using up to 16 schedules
Automation
POL-C1CN
PC4010/4010CF
• 16 modules/system
• 32 readers total
• 1000 access cards
PC4020/4020CF
• 16 modules/system
• 32 readers total
• 1,000 access cards
• Full standalone operation
• Arm/disarm partitions & postpone
auto-arm by access card or access card
and code…from outside the protected
space
• 3 low current outputs per door
• 4 inputs per door…door contact,
request-to-exit input, arm, postpone
auto-arm
• 64 access levels
• 99 seven-day schedules
• 4 holiday groups - 730 holidays
• Individual door-unlock schedules
• Program via keypad, or via computer
with DLS-2 downloading software
• 1.5A regulated power supply
• Power capacity per door:
reader - 125mA max. @ 5VDC
or 250mA max. @ 12VDC
lock - 250mA max. @ 12VDC
• Auxiliary power -125mA @ 12VDC
• Battery required - 12VDC, 7.0AH
• Transformer req’d - 16.5VAC, 40VA
• Fully supervised
Multiple Reader Technologies
• 26 bit standard Wiegand…plus
Polaris…Mag-Stripe Readers/Cards
POL-1 .................... Reader – indoor
POL-1W ................ Reader – outdoor
POL-2 .................... Reader & keypad – indoor
POL-2W ................ Reader & keypad – outdoor
POL-C1CN .............. Mag-stripe card
ShadowProx…Proximity Readers/Cards
SH-VR.................... Std size reader. – indoor/outdoor
SH-1 ...................... Slim-line mullion size reader
4" (10cm) range – indoor/outdoor
SH-2 ...................... Wall-switch size reader
4" (10cm) range – indoor/outdoor
SH-5 ...................... Reader 16" (40cm) range – indoor
SH-5EXT................ Reader 16" (40cm) range – outdoor
SH-C1 .................... Proximity card
SH-K1.................... Proximity keytag
HID…Proximity Readers/Cards
HID-MP5365.......... Slimline reader
4-5" (10-13cm) range – indoor
HID-PR5355 .......... Reader 5-9" (13-23cm) range
– indoor/outdoor
HID-PR5355KP.. .... Reader w/keypad 5-9"
(13-23cm) range – indoor/outdoor
HID-C1325KSF ...... Proximity card
HID-C1345KSF ...... Proximity keytag
POL-1
SH-2
SH-C1
SH-VR
SH-K1
Access
Control
PC4820
Two Reader Access Control Module
Integrated
SYSTEMS
Technology
HID-PR5355KP
T.Rex…Infrared Exit Detectors
KT-TREX-XL ...... Complete with piezo buzzer & tamper
KT-TREX-LT........ No piezo, no tamper
• 11 •• 10 •
• Up to 550mA @ 12VDC power for:
- COMBUS power - local input devices
- local output signals
• 4 form 'C' programmable relays
- contacts rated for 2A @ 30VDC
• 59 programmable output options
• Supervised for low/disconnected battery,
AC power fail, and aux. supply fault
• PT1016 transfmr. incl…16VAC, 40VA
• PC4052CR cabinet, red
• Space for one additional PC4108A module
• Space for two 7AH gel-cell batteries
PC4010CF...... up to 16 modules per
system for 64 relays total
PC4020CF...... up to 16 modules per
system for 64 relays total
PC4612
12 Zone Fire Annunciator
• point annunciation of…
- 10 fire zones
- 2 supervisory zones
- common zone trouble
- common bell trouble
- system trouble
- AC ON LED
• 2 alarm notification circuits
- rated for 1.8A @ 24VDC - FWR
• Outputs supervised for opens, shorts,
and ground fault
• Self-restoring short circuit protection
• PT1024 transfmr incl…28VAC, 160VA
• PC4052CR cabinet, red
• Space for two 4AH gel-cell batteries
PC4010CF ...... 4 panels/system
for 8 bell output zones total
PC4020CF ...... 4 panels/system
for 8 bell output zones total
All the security features of the
PC4010/4020 plus additional fire
features…
• PC4701 Fire Module:
… one 2-wire Class B/StyleB
supervised smoke zone
… one Class B/StyleB
waterflow zone
… dual supervised digital alarm
communicator outputs
… common fire alarm & fire
trouble relays, form 'C', 2A,
30VDC contacts
• All panel & expansion zones are
configurable for: fire, waterflow,
or fire supervisory
• 16VAC, 40VA transformer
PC4010CF/4020CF
Fire Control Panels
Identical to the standard security keypads
but with…red bezels
LCD4520/4521
Plain Language Keypads
UL/ULC Listed Fire Systems*
External battery charger c/w:
• PC4055CR cabinet, red
• PS4085 multi-rate charger module
• PT1012 transformer…12VAC, 160VA
• Space for 60 AH lead-acid battery
PS4350R
Fire System External Battery Charger
Advanced
Communications
• 4 communications formats…
high speed pulse (1400 &
2300 bps), Contact ID, and SIA
Digital
• Fully compatible with the
Links2150
™
& Links2450
™
radio
transmitters
Long Range Radio
• Alternate function of PC4400
module
DVACS
• Fully compatible with Sur-Gard’s
Links1000
™
cellular transmitter
and SKYROUTE
™
cellemetry
transmitter
Wireless Communications
PC4702BP
Dual Bell Zone Panel
PC4204CF
Power Supply/Quad Relay Output Panel
• 3 built-in pager formats
Event-Initiated Paging
7438 C5