Integrated Systems Technology
• Up to 1.0A @ 12VDC power for:
- COMBUS power - local input devices
- local output signals
• 4 form 'C' programmable relays
- contacts rated for 2A @ 30VDC
• 59 programmable output options
• Supervised for low/disconnected battery,
AC power fail, and Aux. supply fault
PC4010 .......... up to 16 modules per
system for 64 relays total
PC4020 .......... up to 16 modules per
system for 64 relays total
PC4204
Power Supply/Quad Relay Output Module
• 16 programmable output zones
• Outputs rated for 50mA @
12VDC
• 59 programmable output
options
• Up to 9 modules/system for
144 total outputs on
PC4010/CF and PC4020/CF
PC4216
16 Low Current Output Module
• PC4108A.... 8 zone input module
• PC4108AT .. 8 zone input module
with tamper (use with
PC5001CP cabinet)
• PC4116........16 zone input module
• 30 programmable zone types
• All zones programmable as NC, EOL, DEOL
• 250mA, 12VDC aux. power for local devices
• Add up to 56 zones on PC4010/CF
• Add up to 112 zones on PC4020/CF
PC4108A/4116
8/16 Hardwire Zone Expansion Modules
PC4010
• 8 zone main panel
• Expandable to 64 zones
• 1 addressable loop for up
to 56 addressable devices
• 16 LCD keypads/system
• 4 partitions
• 1,000 user codes
• 3,000 event buffer
• 5 account numbers
3 phone numbers
PC4020
• 16 zone main panel
• Expandable to 128 zones
• 2 addressable loops for up
to 112 addressable devices
• 16 LCD keypads/system
• 8 partitions
• 1,000 user codes
• 3,000 event buffer
• 9 account numbers
3 phone numbers
PC4010/4020
Security Control Panels
• 1 supervised bell zone
• PCLINK
™
for local
upload/download
• Remote upload/download
• Supervised digital
alarm communicator
•
Opt. attack-resistant cabinet
• Space for two 7AH
gel-cell batteries
• Two line, 32 character display
• Adjustable brightness & contrast
• Backlighting Boost on LCD4501
for low light conditions
• Display zone and system status,
trouble conditions, event buffer,
and system instructions
• Global or partition operation
• 4 keypad-activated alarms…
panic, auxiliary, fire, & duress
• 5 programmable keypad
functions
• Separate function keys on
LCD4501
• Trouble & Armed LEDs on
LCD4500
• Trouble, Armed, & Ready LEDs
on LCD4501
• Trouble buzzer
• Tamper versions available
LCD4500/4501
Plain Language Keypads
COMBUS
System Expansion
• Hardwired system expansion is
simple and economical using
standard, non-shielded, 4
conductor station wire.
• All hardwired system keypads,
zone input modules, access control
modules, output modules, Escort
automation, fire modules,
annunciators, etc., are connected
to the system via the COMBUS.
• System components may be
connected up to 1,000ft (305m)
from the main control panel.
•
Up to four 1,000ft runs can be used.
• 8 • • 9 •
Point or graphic display of zone, partition,
and system status c/w:
• Egg-crate backplane for flexible indicator
location
• Pre-printed point display transparency
• Clear transparencies (2) for custom
graphic printing
PC4632 … 32 indicator capacity c/w:
• 8.5" x 11" (21.6 x 27.9cm) display area
• One PC4216 low power output module -
capacity for 2 modules
• 16 LEDs
• PC4032C cabinet, beige
PC4664 … 64 indicator capacity c/w:
• 11" x 17" (27.9 x 43.2cm) display area
• Two PC4216 low power output modules -
capacity for 4 modules
• 32 LEDs
• PC4064C cabinet, beige
PC4632FT … opt. flush trim for PC4632
PC4664FT … opt. flush trim for PC4664
PC4632/4664
32 & 64 Zone
Point/Graphic Annunciators
External battery charger c/w:
• PC4055C cabinet, beige
• PS4085 multi-rate charger module
• PT1012 transformer…12VAC, 160VA
• Space for 60 AH lead-acid battery
PS4350
External Battery Charger
Use 2-wire addressable loops to easily
expand to full system zone capacity
without the added cost
of system expansion modules
Addressable
Expansion*
Compatible With All
DSC Addressable Detectors
• AMA-100 Glassbreak Detector
• AMS-220 Series…Photoelectric Smoke
Detectors
• AMB-300 PIR Motion Detector
• AMB-500 Ceiling Mount PIR
• AMB-600 Dual Pet Immune PIR
• AMP-700 Series…Contact Modules
Compatible With All DSC Wireless
Controls and Detectors
Wireless Controls:
• WLS908 Wireless Panic Pendant
(1)
• WLS909 Wireless Key
• WLS910 Wireless Keypad
Wireless Detectors
(1)
:
• WLS904 PIR Motion Detector
• WLS906 Photoelectric Smoke Alarm
• WLS907 Universal Transmitter
(1)
each occupies 1 wireless zone
• Capacity … Wireless zones - PC4010…56
- PC4020…64
… 16 WLS909 Wireless Keys
… 4 WLS910 Wireless Keypads
(in addition to hardwired keypads)
• All wireless detectors are fully supervised for
communication integrity
• 900MHz True Spread Spectrum Technology
• Easy sensor enroll process
PC4164
Wireless Module
Wireless Expansion
PC4400
RS 232 Printer/DVACS Interface
• Use as DVACS communicator or printer interface
• Print time and date stamped report of: alarms,
openings/closings, diagnostic messages
• Supports 300, 1200, 2400, 4800 BPS serial printers
(see page 14 for addressable device details)
(see page 13 for wireless device details)